Detectors
Types, successors and bases
Which detectors from year of manufacture 2000 onwards must be replaced, what is still available, which detector replaces older types and when a new base is needed – with the manufacturers’ order numbers.
Select the manufacturer of your fire alarm system. You will find the type designation or article number on the detector’s type plate.
Manufacturer
Detectors by manufacturer
ESSER
Series 9000, 9200, IQ8Quad, ES Detect, self-test detectors (-ST) and aspirating smoke detectors (TITANUS EB, FAAST, VESDA-E).
Bosch / SONAX-ALARM
Series 420, AVENAR detector 4000 (425), Series 320, 520 and 500 – SONAX-ALARM identical in construction.
NSC (Hochiki / Apollo)
Hochiki ESP and CDX as well as Apollo XP95, Discovery, Soteria, Orbis and Series 65.
Labor Strauss, MEP, Hertek
These systems work with Apollo detectors and bases – the Apollo manufacturer code is decisive.
Hekatron
Integral MTD 533X and CMD 533X, modernisation detectors MSD/UTD 523 and MMD 140/150.
Detectomat
Loop3000 (PL 3200, PL 3300 incl. version 2025) and conventional detectors CT 3000.
Telenot
hifire 4000 BMT / 4400 / 4100 XS with Loop 4000 (4400IT, 4401IT, 4402), Loop 3000 and conventional detectors CT 3002/3005.
Siemens
AlgoRex, SIGMALOOP, Sinteso (FDOOT241) and Cerberus PRO (OP720, OH720, HI720, OOH740) – incl. base adapters.
Securiton
SecuriStar MCD 573X, CCD 573X, SCD/MCD 573 and STD 531, aspirating smoke detectors ASD – with notes on Hekatron compatibility.
Notifier
OPAL series (NFXI/NFX), SMART4, self-test detectors NFSTI, Series 700 as well as conventional detectors Series 800 and ECO 1000.
Zettler (Johnson Controls)
Generation 6 (830/850 P, H, PH, PC), Series 801 and Ex detectors – with bases 4B, 4B-I, 4B-C.
WAGNER
Aspirating smoke detectors TITANUS REX, TOP·SENS, PRO·SENS, FUSION, MICRO·SENS and RACK·SENS – with detector modules.
Xtralis (VESDA)
VESDA-E VEU, VEP, VES, VEA, LaserFOCUS and Laser Industrial – successors for VLP, VLC and VLS.
Minimax / HELIOS
Addressable loop detectors OMX95/OWMX95/WMX95, UniVario WMX5000/FMX5000/YMX5000 and aspirating smoke detectors HELIOS AMX.
Stratos
Aspirating smoke detectors HSSD 2, Micra 10/25/100 and ModuLaser detector modules – with NSC order numbers.
Important
Before ordering
- Check the panel: Whether a replacement detector can be operated on your fire alarm control panel depends on the panel, loop or line technology and programming. We check this using your detector list and programming file.
- Replacement interval: Smoke and multi-sensor detectors after 5 years at the latest, or after 8 years with automatic contamination compensation and testing in accordance with the manufacturer’s specifications – details under Deadlines & standards.
- Change of detector series: New bases, different detector types or a changed number of detectors may constitute a significant modification – see expert inspection and fire brigade.
- Installation by a specialist company only: Replacement and repair of detectors in fire alarm systems required under building law are part of maintenance and are reserved for a specialist company certified to DIN 14675 – even if you only buy the detectors from us. Details under Legal situation.
- Order numbers are given on the manufacturer pages, each with source and date.
- Trademarks: All manufacturer, brand and product names mentioned are the property of their respective owners and are used solely for identification. Image credits are given on the manufacturer pages and in the Legal notice.
Not sure which detector is installed at your site?
Send us your detector list or a photo of the type plate. We will name the suitable replacement and tell you whether new bases are needed.
